Powertank Integrated UV System
Powertank Integrated UV System – For Fixed Speed Units
In stock
- Established 1975
- Trusted by thousands of customers
Powertank Integrated UV System – For Fixed Speed Units
INSTALLATION & USE
UV systems deactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, and harmful bacteria like Legionalla & E.Coli which may be present in some incoming water supplies.
More about this product
STAGE 1: FINE SEDIMENT REMOVAL
Stage 1 is a 5 micron sediment filter cartridge with antimicrobial protection provided by a silver based antimicrobial agent included in the plastic matrix with a specific technology. The filter housing also has antimicrobial abilities to prevent the build up of bacteria and algae within the housing.
STAGE 2: ULTRA VIOLET DISINFECTION UNIT
Stage 2 is a Viqua UV disinfection system for the purposes of inactivation of bacteria and viruses in the incoming water supply. This UV system has an integral countdown timer to indicate when the UV lamp needs to be replaced. UV lamps degrade over time and must be replaced every 12 months.
BENEFITS TO UV DISINFECTION
Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli, and viruses not visible to the naked eye.
Specially designed and tested Sterilume™-EX lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification. Always use Viqua genuine replacement lamps and sleeves.
The system is simple to maintain and service allowing for easy lamp replacement.
Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
The controller visually displays the remaining lamp life and will go into alarm if the lamp fails. Monitored systems are equipped with a UV sensor which provides a continuous readout of UV intensity.
The controller has a sealed case to prevent damage from accidental water intrusion and is fully CSA and CE compliant.
Monitored systems allow for the installation of an optional solenoid valve which will stop the flow of water through the chamber should the UV performance fall below a safe level.
CONSTRUCTION
Connection Size: 1″ BSP
Power Consumption: 35W
PERFORMANCE RANGE
Flow Rates: 8 GMP (36 lpm)
Maximum Operating Pressure: 6 Bar
Ambient Water Temperature: 2-40°C (36-104°F)
*Max Flow Rate @ 16mj/cm2: 3.6m3/hr
*Max Flow rate @ 30mj/cm2: 2.0m3/hr
Standard delivery:
Standard delivery is free for all orders except for some low cost/low margin items where standard delivery is £6.50. Some difficult to transport goods also have a varying carriage charge applied.
Please contact us for the estimated standard delivery times of the products that we have in stock, either by calling 01473 719950, or by dropping us an email at info@anglianpumping.com.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £15.00 + vat delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.